MERLINKEDI · FIRE DOOR SYSTEMS

MK-SG90 Glazed Steel Fire Door System — 90 Minute Rating

Glazed steel fire door system with hose-stream verified vision lites, mineral-core construction, rated 90 minutes under UL 10C / NFPA 252. Certified single swing 1120 × 2355 mm. Project pricing on request.

UL 10B / 10C LISTED

NFPA 252 TESTED

MADE IN ANQING

Ref MK-SG90

Request a Project Quote
SCENE 02 · THE RATING
Twenty. Sixty. Ninety.

Minutes the leaf holds the line — chosen per project, certified per leaf. UL 10B / UL 10C / NFPA 252 endurance, hose stream included. Your specifier picks the number; the furnace has already agreed.

0 MIN 30 90 180 540°C 945°C
SCENE 03 · THE PROOF · UL 10C / ASTM E119
25°C
ELAPSED · 000 MIN

The standard curve, traced by your scroll — past 900°C at minute ninety, held to the end of the run. Then the door is measured again, on the cold face.

The 90-minute steel system with the vision panel that keeps supervision and daylight in play — corridor sightlines and code-required observation without giving up the rating.

Specifications

Fire performance90 minutes — Intertek report 250612025SHF-004 (steel door + frame, GFM-MLKDAS-L-1224 A90Mins, tested 2025-12-29) · GB 12955-2008 Class A (1.5 h)
Certified single opening — leaf1120 × 2355 mm, single swing (ATM 91995)
Certified single opening — frame1130 × 2365 mm · steel frame stop 15 mm · min throat opening 84 mm (ATM 91996)
GB max envelopesSingle 1200 × 3500 mm — GFM-1235-dk5 Class A (CQM23335301012361) · pair 3000 × 3500 mm — GFM-3035-dk5 Class A (CQM23335301012360)
HardwareListed mortise or cylindrical locks · min latch-bolt throw 1/2 in (12.7 mm) · min one single-point standard latching (ATM 91995)
Edge sealingCategory G intumescent edge seal (Category B label) · optional “S” smoke label with listed Category H smoke & draft gasket (ATM 91995)
Hose streamIncluded in the 90-minute positive-pressure evaluation (ATM 91995)
Vision glazingEngineered per opening; certified glazing envelope reference: max 330 × 330 mm, min bite 12.5 mm, min 367.5 mm edge distance (Listing 92609)
StandardsUL 10C (2016) · UL 10B (2008, R2020) · NFPA 252 (2022) · CAN/ULC S104 (2015, R2020) · NFPA 80 installation

Evidence & documentation

  • Intertek test report 250612025SHF-004 — 90-minute steel fire door + frame (30 pages) · View PDF
  • Authorization to Mark 91995 — single-leaf steel fire door, 90 min · View PDF
  • Authorization to Mark 91996 — steel door frame, 90 min · View PDF
  • Full certification wall — reports, authorizations and listings · certifications

Every quote ships with the matching test report, listing extract and hardware schedule. Request a project quote.

THE RECORD

Paper behind the rating.

01

Intertek Listing Information

The listing behind every shipped leaf.

02

Authorization to Mark

Permission to stamp, earned per certification.

03

Fire Test Reports

Furnace runs, hose stream, cold-face measurement.

04

Domestic Certification Portfolio

The full domestic record for local code.

Put this door in your drawing set.

Send the opening schedule and rating requirement — you get drawings, hardware schedule and a quote from the factory in Anqing.

Request a Project Quote